Air

A building should only let in outdoor air at design points where it is intended. The ventilation should be efficiently distributed to areas where it is required. Tools in this category will help diagnose problems with the building envelope and air distribution within the space. Measurements possible with these tools include tracking air pressure, air quality, leakage, and air flow.

Sling Psychrometer

Measures: 
RH, Wet/Dry-Bulb Temperatures

The Sling Psychrometer is an easy and affordable way to measure relative humidity levels quickly and accurately. It is ideal for many applications, including the measurement of conditions within indoor environments, storage areas, laboratories and more.

Sensor Range (Accuracy): 
10% to 100% R.H., for dry-bulb temperatures of 30° to 100°F (–5° to 50°C). ± 1 °F (model 0012-7012)
Sub-Category: 

VOC and Temperature Monitor w/ Data Logging, Bapi

Measures: 
Volatile Organic Compounds

Humans exhale Volatile Organic Compounds (VOCs) as well as CO2. The BAPI sensor is able to measure these VOCs, therefore it is as good an indicator of space occupancy as a CO2 sensor. The BAPI Sensor is different from other VOC sensors because it has been optimized for Demand Controlled Ventilation (DCV). Using a calibration algorithm, the sensor value is converted to an output with a high correlation to a CO2 level. This lets you use ASHRAE’s occupancy-based VRP schedule to ventilate.

Sensor Range (Accuracy): 
0 to 2,000 CO2 PPM equivalent
Compatible Tools: 
HOBO U12-012 & HOBO Temperature Sensor
Sub-Category: 

Carbon Dioxide and Temperature Monitor w/ Data Logging, Veris

Measures: 
Carbon Dioxide

The CDE and CWE are non-dispersive infrared (NDIR) sensors designed for measuring environmental CO2 concentration in ventilation systems and indoor living spaces. Their measurement range of 0 to 2000 ppm makes them compliant with ASHRAE and other standards for ventilation control
The CWE/CDE Series provides a user-selectable 4 to 20 mA or 0 to 10 Vdc output for versatility. Microprocessor-based digital electronics and a unique self-calibration algorithm improves long-term stability and accuracy.

Sensor Range (Accuracy): 
±30 ppm ±2% of measured value*
Compatible Tools: 
HOBO U12-012 & HOBO Temperature Sensor
Sub-Category: 

Carbon Dioxide and Temperature Monitor w/ Data Logging, BAPI

Measures: 
CO2 measured range of 0 to 2,000 ppm with a field selectable output of 0 to 5 or 0 to 10 VDC

The BAPI-Stat 3 CO2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building’s HVAC strategy. It has a field selectable output of 0-5 or 0-10V and has been optimized for periodically unoccupied areas. The unit features continuous automatic air pressure compensation for accurate readings despite the weather or the altitude of the installation, which earned the sensor a 2012 AHR Expo Innovation Award. The unit is available as CO2 alone or with temperature, humidity, temp setpoint and override.

Sensor Range (Accuracy): 
RH: ±2%, VOC/CO2 unspecified
Compatible Tools: 
HOBO U12-012 & HOBO Temperature Sensor
Sub-Category: 

Digital Pressure Transducer - Dry Media, Veris

Measures: 
Differential Pressure

The digital PXU Series differential pressure transducers utilize highly accurate, microprocessor profiled sensors. Designed to monitor duct and room pressure in commercial buildings, the PX Series offers exceptional job-site flexibility. The PXU features seven field-selectable ranges, allowing just one model to cover applications for 0-0.1” to 0-10” W.C. The directional mode jumper is used to configure the transducer in unidirectional or bidirectional mode for room and building static pressure applications. All models feature a pushbutton and digital input terminal to zero the output.

Sensor Range (Accuracy): 
Uni-directional 0.1/0.25/0.5/1.0/2.5/5/10” W.C. 25 Pa/50 Pa/100 Pa/250 Pa/0.5 kPa/1 kPa/2.5 kPa F.S. switch selectable Bi-directional ±0.1/0.25/0.5/1.0/2.5/5/10” W.C. 25 Pa/50 Pa/100 Pa/250 Pa/0.5 kPa/1 kPa/2.5 kPa F.S. switch selectable
Sub-Category: 

Shortridge Flow Hood

The FlowHood is a much more convenient alternative to time-consuming multiple velocity readings across air diffusers, as this instrument eliminates the need for the calculations necessary to convert the average velocity into air flow. The AirData Multimeter utilizes the Series 8400 FlowHood Kit for back-pressure compensated measurement of air flow. The FlowHood unit captures and directs the air flow from an outlet, or inlet, across the highly sensitive flow sensing manifold within the FlowHood base.

Sub-Category: 

FLEX.US Ultrasound Leak Detector

Measures: 
Air Leak

The SDT FLEX.US detector works like a super microphone, sensitive only to high frequency ultrasounds. Using a sensitive piezoelectric crystal as a sensor element, minute high frequency sound waves excite or “flex” the crystal creating an electrical pulse that is amplified and then “heterodyned” or translated into an audible frequency that the technician can hear through a pair of noise reduction headphones. See attachments for additional information.

Sub-Category: 

Fluke PV350 Multimeter Adapter

Measures: 
Pressure

The PV350 Pressure/Vacuum Transducer Module (the module) measures gauge pressure; the difference between atmospheric (barometric) pressure and the pressure (or vacuum) applied to the pressure port on the transducer. It then converts that measurement to 1 mV dc per unit. A module and a high-performance digital multimeter (DMM) with min/max function become a datalogger capable of measuring peak high and peak low.

Sub-Category: 

Carbon Dioxide and Temperature Monitor

Measures: 
Carbon Dioxide and Temperature

Identify areas with low or substandard ventilation. Identify hidden energy savings in over-ventilated spaces. Determine if ventilation is a factor in air quality complaints. Locate the presence of combustion fumes from vehicles and appliances. Use as a reference to calibrate wall mounted CO2 sensors. Telaire 7001 with Onset cable to hook to hobo and 120 V. adapter 6V, 500mA output. See attachments for additional information.

Sensor Range (Accuracy): 
Telaire 7001 operating range: 32°F to 122°F (0°C to 50°C), 0 to 95% RH, non-condensing Display resolution: ±1 ppm Accuracy: ±50 ppm or 5% of reading, whichever is greater Response time: <60 seconds for 90% of step change Warm-up time: <60 seconds at 72°F (22°C)
Compatible Tools: 
HOBO U12-012 & Temperature Sensor TMC6-HD/TMC20-HD
Sub-Category: 

Smoke Pen

The S220 Smoke Pen contains a patented smoke-emitting wick that is lit with a cigarette lighter or match. The glowing tip emits smoke for as long as you need. A single wick will emit smoke for up to half hour, but can be start and stopped by capping and relighting as needed. There is no waste; no mess—only safe non-toxic smoke. The unused portion of the wick stores safely in the barrel of the pen.